Those engines don't have PIPE_CONTROL so we can't do
ANV_TIMESTAMP_CAPTURE_AT_CS_STALL but we can support measurement
by changing the capture type to ANV_TIMESTAMP_CAPTURE_TOP/END_OF_PIPE
Right now this issue is only reproduced in Xe KMD without setting
any special parameters(other than INTEL_MEASURE) because Xe KMD allows
the usage of copy engine while i915 can't due TRTT restrictions.
Signed-off-by: José Roberto de Souza <jose.souza@intel.com>
Reviewed-by: Lionel Landwerlin <lionel.g.landwerlin@intel.com>
Part-of: <https://gitlab.freedesktop.org/mesa/mesa/-/merge_requests/26882>